CANopen Bus Coupler BK5120
BK5120 | CANopen Bus Coupler
The BK5120 “Economy plus” Bus Coupler connects the CAN bus system to the electronic terminal blocks, which can be extended in modular fashion. One unit consists of one Bus Coupler, any number of up to 64 terminals and one end terminal. With the K-bus extension technology, the BK5120 allows the connection of up to 255 spatially distributed Bus Terminals to one Bus Coupler.
The Bus Coupler works on the CAN protocol basis as defined in ISO 11898. In addition to network services, CANopen also determines the data allocation for automation systems applications and has established itself as an open CAN application layer. The Bus Coupler supports all types of CANopen communications and can also be used without difficulty in manufacturer-specific CAN environments due to the simple structure of this protocol definition. The firmware can be updated via the configuration interface.
Parameterising can also be carried out using any CANopen configuration tools. For this, EDS data files are available, which describe all the setting options for the CANopen coupler. For most applications, however, no configuration is necessary, as CANopen provides practical default values for all parameters.
System data | CANopen | BK5120 | |||||||
---|---|---|---|---|---|---|---|---|
Number of I-O stations | 64 (BK5120: 255 with K-bus extension) | |||||||
Number of I-O points | depends on the structure | |||||||
Data transfer medium | screened, twisted copper cable, 2 x signal, 1 x ground (recommended) | |||||||
Max. cable length |
|
|||||||
Data transfer rates |
|
|||||||
PDO modes | synchron, cyclic, event driven, polling |
Technical data | BK5120 |
---|---|
Number of Bus Terminals | 64 (255 with K-bus extension) |
Max. number of bytes fieldbus | 16 Tx-Rx PDOs |
Digital peripheral signals | 960 inputs-outputs |
Analog peripheral signals | 60 inputs-outputs |
Configuration possibility | via KS2000 or the controller |
Number of PDOs (CANopen) | 16 Tx16 Rx |
Additional CANopen features | life, node guarding, emergency object, variable mapping, store-restore |
Data transfer rates | up to 1 Mbaud |
Bus interface | 1 x open style connector, 5-pin, included |
Power supply | 24 V DC (-15 %+20 %) |
Input current | 70 mA + (total K-bus current)4, 500 mA max. |
Starting current | approx. 2.5 x continuous current |
Recommended fuse | ≤ 10 A |
Current supply K-bus | 1750 mA |
Power contacts | 24 V DC max.10 A max. |
Electrical isolation | 500 V (power contact-supply voltage Bus Coupler) |
Weight | approx. 150 g |
Operating-storage temperature | -25…+60 °C-40…+85 °C |
Relative humidity | 95 %, no condensation |
Vibration-shock resistance | conforms to EN 60068-2-6EN 60068-2-27 |
EMC immunity-emission | conforms to EN 61000-6-2EN 61000-6-4 |
Protect. class-installation pos. | IP 20variable |
Approvals | CE, UL, Ex, GL |
Accessories | |
---|---|
KS2000 | configuration software for extended parameterisation |
Cordsets | cordsets and connectors |
FC5101 | FC5102 | CANopen PCI fieldbus cards |
Related products | |
---|---|
BK5110 | CANopen Coupler for up to 64 digital Bus Terminals |
BK5150 | CANopen “Compact” Bus Coupler for up to 64 Bus Terminals (255 with K-bus extension) |
BK5151 | CANopen “Compact” Bus Coupler for up to 64 Bus Terminals (255 with K-bus extension) |
LC5100 | CANopen “Low Cost“ Bus Coupler version for up to 64 digital Bus Terminals (255 with K-bus extension) |
BC5150 | CANopen “Compact” Bus Terminal Controller for up to 64 Bus Terminals (255 with K-bus extension) |
BX5100 | CANopen Bus Terminal Controller for up to 64 Bus Terminals (255 with K-bus extension) |
CX8051 | CANopen Embedded PC, slave |
System | |
---|---|
CANopen | For further CANopen products please see the system overview |
BK5120 - CANopen Bus Coupler - Beckhoff VietNam
- AEG POWER SOLUTIONS
- AIRA VALVE
- AT2E
- Ashcroft
- BARKSDALE
- Baumueller
- BKW KUEMA
- BECKHOFF
- Block Automation
- Bircher
- CEMB
- CELEM Power Capacitors
- cs instruments viet nam
- CEIA Việt Nam
- Dillon
- Dwyer Instruments
- DECA
- Endress Hauser
- ELCO HOLDING
- Framo Morat
- Fotoelektrik Pauly
- HANS SCHMIDT
- FOXBORO
- Gastron
- IWATSU
- Grant Instruments
- IBA Ag
- IPF-Electronic
- INTORQ
- KOGANEI
- KAWAKI
- KYOWA
- KENDRION
- KNICK
- KELLER ITS
- krohne Việt Nam
- Mark-10
- Masoneilan
- MATSUSHIMA
- Matsui
- Matsushima
- OMEGA
- Orion Instruments
- Ohkura
- Nireco
- Pietro Fiorentini
- PILZ
- Pci instruments.
- Pce Instruments
- Rotork
- RE-SPA
-
Redlion
- Bộ điều khiển, thu thập dữ liệu Redlion
- Màn hình HMI & Màn hình hiển thị, bộ đếm Redlion
- Cảm biến, điều khiển quá trình
- Giải pháp truyền thông ethernet
- Giải pháp truyền thông di động M2M Redlion
- Bộ chuyển đổi truyền thông redlion
- THIẾT BỊ ĐIỀU KHIỂN - MÀN HÌNH HMI
- Các loại cảm biến, thiết bị điều khiển quá trình
- Riel
- SCANLAB
- Sauter EU
- Sauter Controls
- Shimadzu
- sitec Việt Nam
- S-E-G
- Tianjin Jinbo
- Taptone
- Teclock
- TDK Lambda
- tantronic
- thwing albert
- UTILCELL
- Vibro Meter
- Wise Control Việt Nam
- Zama Sensor
- YOUNG TECH
- Và Nhiều Hãng Khác
-
Trực tuyến:8
-
Hôm nay:361
-
Tuần này:3089
-
Tháng trước:9461
-
Tất cả:2380997